10. Troubleshooting

Symptom
Alarm: No fire/fuel
Lack of fire
Wrong lightning up
Too moisture pellet
Boiler
Clogged primary air channels
cannot reach
programmed
Clogged heat exchanger's pipes
temp.
Damaged gasket on blower's or
burner's flange
Damaged blower
Clogged or unproper chimney
Boiler is fuming
Strong wind forces fumes into the
chimney
Gasket leak
Door is fuming
Damaged rope
No voltage in the grid
Controller doesn't
Damaged wire
work
Damaged controller
Damaged bearings
Damaged capacitor
Loud blower
operation
Loosen fixing of blower
Dirty rotor blades
Reason
Action
Refill hopper acc. to point „Lightning up"
Check „Lightning up"
Check moisture – use pellet with required
parameters
Call service – after-warranty service
Clean pipes or call service – after warranty
service
Replace – after-warranty service
Replace – after-warranty service
Get the chimney-sweeper opinion
Consider installation of devices regulating
chimney draught
Regulate the door's hinges
Replace the rope – after-warranty service
Check the protection devices in the electric
installation
Wire and connection control
Call the service
Call the service - replace the blower
Call service – replace the capacitor
Fixing control, screw in
Control, cleaning
25