4. Troubleshooting

Symptom
Boiler cannot reach
Wrong lightning up
set temperature
Too humid wood
Clogged primary air channels
Clogged secondary air pipes
Polluted heat exchanger's pipes
Unproper mix of air with wood
gases
Damaged nozzle
Smoking from fan gasket
Damaged fan
Smoking from
Strong wind force exhaust gases
loading door
into the chimney
Unproper chimney parameters
Smoking from door
Leakiness from door
Used rope - leak
Damaged door
Controller doesn't
No voltage in the grid
work
Damaged fuse
Damaged wire
Damaged boiler sensor
Damaged controller
Fan doesn't work
Damaged fan
Fan blades blocked
Loud work of fan
Damaged bearings
Damaged condenser
Loosen fixing of fan
Polluted fan blades
Pitch in fan casing
Weak work of fan
Polluted fan blades
Fan flap clogged with pitch
Explosions In boiler
Wrong lightning up
Too low chimney draft (below 10 Pa)
Too big chimney draft (above 20
Pa)
Too dry wood (humidity below
15 %)
Polluted heat exchanger's pipes
22
Reason
Action
Check. 5.1 „Lightning up"
Humidity control – use wood with proper
parameters
Call service – after warranty service
Call service – after warranty service
Call service – after warranty service
Call service – after warranty service
Replace – after warranty service
Replace – after warranty service
Replace – after warranty service
Consider installation of appliances supporting
chimney draft (WKO)
Rebuild chimney, chimneys weeper assistance
Door adjustment according to 6.3.
Rope replacement or call service - after warranty
service
Door replacement
Check electric installation
Fuse replacement
Wire control or replacement
Call service
Call service
Fan replacement – call service
Check and clean fan
Call service- fan replacement
Call service – condenser replacement
Fixing control, screw in
Control, cleaning
Control, cleaning
Control,cleaning
Clean or call service
Check 5.1 "Lightning up"
Rebuild chimney. Install exhaust fan WKO
Install draft stabilizer
Mix with wood with higher humidity content
Clean pipes or call service