PROGRAMMING
5. PROBE HUMIDITY
Current humidity that the probe is detecting. Displays "--" if no probe is plugged in. Includes a trend
indicator that signals a rise, steady, or fall in humidity within the last hour.
6. CONTROLLER MODE
Displays the mode that the controller is currently in. Pressing the mode button cycles through the
available modes.
7. STATUS ICONS
Flashes or displays the alert icons from the controller. Icons include TIMER ALERT and DISPLAY
LOCK.
8. CURRENT TIME
Displays the current time. The internal battery sustains the clock so it does not default to 00:00 if
power is cut off. Please see page 18 for instructions on how to set up the clock time.
9. FAN SPEED
Displays the current speed in which the fan is running. Includes a trend indicator that signals if the
fan is currently rising, falling or holding steady.
10. COUNTDOWN
Displays TO ON or TO OFF countdown to show the amount of time before the timer to on, timer to
off, cycle, or schedule modes activates or deactivates the fan. TO ON represents the amount of
time that is left before the fan turns on. TO OFF represents the amount of time that is left before the
fan turns off.
11. USER SETTING
Displays the value you have set for the current mode that you are in. Press the up or down button
to adjust the value.