OFF
0102006
Figure 3.1.1: Battery Disconnect Switch
LUBRICATION
Refer to Table 3-1 for lubrication intervals and Figure
3-2 for location of items that require lubrication ser-
vice. Refer to the appropriate sections for lubrication
information on the hydraulic tank and filter.
GREASE FITTINGS
Wipe each grease fitting before and after greas-
ing. Using a lithium based multipurpose grease in
a grease gun, pump the grease into the fitting until
grease begins to appear at the edges of the pivot.
Wipe off any excess grease.
LINKAGE GEARS
1. Raise platform fully.
2. Using another work platform or ladder, get up
high enough to comfortably reach the gears.
3. Use a long handled brush to apply gear linkage lubricant (part number): 509594-000.
4. Lower the platform after greasing.
STEERING LINKAGE
Apply one or two drops of SAE 10 W or spray lube oil to each pivot and grease upper and lower king
pin bearing.
SL26/30SL
ON
B
A
T
T
E
R
Y
C A U T I O N
!
DO NOT use hands to apply grease to the gears. DO NOT stand
under the elevating assembly nor have any body part within this
SERVICE AND REPAIR
Figure 3.1.2: Battery charge indicator
Figure 3-2: Lubrication points
Grease fittings
1
2
Linkage gears
!
area.
3
Steering linkage
Page 3 - 5