TROUBLESHOOTING
DIAGNOSTICS
The EZcal display has a number of diagnostic tools to aid troubleshooting. To access these with the
machine switched on, press and hold "ESC" for 5 seconds until "#### MENU: HELP: PRESS EN-
TER" is displayed. Press "ENTER" for a top level fault message.
For more detailed diagnostics from the top menu, scroll right to "DIAGNOSTICS" and press
"ENTER". A list of diagnostics sub menus become available as folllows:
SYSTEM
The information listed below is relevant to this machine (ignore any other data).
MODE: Ground or platform mode selected.
•
SUPPLY: The supply voltage at the GP400.
•
VALVE SUPPLY: Valve supply "ON" or "OFF".
•
TILT: This is the platform tilt angle in X and Y.
•
From tilt, press "ENTER" for chassis tilt angle in X and Y.
AXLE: Press "ENTER" for "AXLE Tilt angle".
•
TILTED: "YES" if the platform angle exceeds 2 degrees in X or Y.
•
HEIGHT: The platform height as a percentage of full elevation.
•
LOAD: The platform load as a percentage of full Safe Working Load (SWL).
•
OVERLOADED: "YES" if the platform load exceeds 120% of the Safe Working Load (SWL).
•
LAST MOVED: The last movement.
•
ELEVATED: "YES" if the height is above the elevation height.
•
PLATFORM
The information listed below is relevant to this machine (ignore any other data).
•
TRIGGER: "ON" if the joystick trigger is activated.
JOYSTICK: Gives the percentage of joystick deflection.
•
•
FWD/UP: "ON" if the joystick is pushed forward beyond its "ON" position for "ON/OFF" appli-
cations eg "MANUAL LEVELLING" forwards.
•
REV/DOWN: "ON" if the joystick is pulled backward beyond its "ON" position for "ON/OFF"
applications eg. "MANUAL LEVELLING" backwards.
LEFT: "ON" for steer left.
•
Right: "ON for steer right.
•
GROUND
The information listed below is relevant to this machine (ignore any other data).
UP: "ON" for lift selected.
•
DOWN: "ON" for lower selected.
•
INPUTS
This provides the condition for all digital inputs to the GP400 controller in the ground control box and
the matrix board in the platform control box. Refer to the electrical circuit diagram and the I/O list for
details of each input function.
ANALOGS
This provides the voltage on the analogue inputs to the GP400 controller in the ground control box
and the MATRIX board in the platform control box. Refer to the electrical circuit diagram and the I/O
list for details of each input function.
OUTPUTS
This provides the condition for all digital outputs from the GP400 controller in the ground control box
and the MATRIX board in the platform control box. Refer to the electrical circuit diagram and the I/O
list for details of each output function.
Page 4 - 4
SL26/30SL