CALIBRATE HEIGHT

This machine has an angle transducers (EZfit) attached to the boom which allows the ECU to
calculate the platform height by comparing the boom angle with the platform angle.
HEIGHT CALIBRATION PROCEDURE
If "LEVEL" hasn't been calibrated, then follow the procedure (refer to page 3-17) to "CALIBRATE
LEVEL" first.
1. Place the machine on a firm level surface and level the platform.
2. Switch the machine to ground controls.
3. Press and hold "ESC" for 5 seconds until "#### MENU: HELP: PRESS ENTER" is dis-
played.
4. Scroll to "ACCESS LEVEL" and press "ENTER".
5. Enter code 2222 for "ACCESS LEVEL 2" and press "ENTER".
6. Scroll to "SETUPS" and press "ENTER".
7. Scroll to "HEIGHT SETUPS" and press "ENTER".
8. Scroll to "CALIBRATE HEIGHT" and press "ENTER".
9. The question "PLATFORM DOWN" pops up. Check that the platform is fully lowered and
press "ENTER".
10. The suggestion "PLEASE LIFT" pops up. Use the lift controls to fully elevate the platform.
11. The suggestion "PLEASE LOWER" pops up. Use the lower control to fully lower the plat-
form.
12. The suggestion "CAL DATE" pops up. Use the up and right arrows to enter the calibration
date and press "ENTER".
13. The suggestion "FINISHED" pops up. Height calibration is now finished.
SL26/30SL
Angle transducers
Figure 3-13: EZfit location
W A R N I N G
!
If the GP400 control module, either of the boom angle transducers or either
of the CANtilt level sensors are replaced and/or moved, platform height on
the full system must be recalibrated using the procedure provided. Failure to
do so could result in serious injury or death.
SERVICE AND REPAIR
!
Page 3 - 19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl30rte