13. Set the motor running time

In order to be able to use all of the functions, such as ventilation position and sunshine position,
it is vital that the motor running time is correctly configured beforehand.
The running time can be configured directly with the Troll Basic DuoFern or you can enter it in
the central DuoFern controller (e.g. HomePilot®).
NOTE
◆ Tubular motor running times can vary depending on temperature. For this reason, targeted
movement to a specific position is subject to certain tolerances.
◆ The motor running time must be reconfigured if the end points are changed.
i

13.1 Setting the motor running time with the Troll Basic DuoFern

1.
+
2.
+
3.
26
Move the roller shutters or blinds to the lower
end point.
Simultaneously press and hold the [ Timer ] and
[ Up ] buttons.
After approx. 4 seconds, the solar LED flashes red and the
roller shutters or blinds move to the upper end point.
Release both buttons as soon as the roller shutters
stop at the upper end point.
The running time will be timed and stored during the up cycle.