28. Technical Specifications

External dimensions control unit [ 1 ]:
Nominal voltage:
Max. switching capacity:
Standby consumption:
Extension inputs:
Connection diameter:
Installation depth:
Permissible ambient temperature:
Data retention:
Protection class:
Transmission frequency:
Transmission power:
Range:
i

29. Factory settings

Automatic:
Automatic time:
Automatic dawn function:
Automatic dusk function:
Automated solar function:
Sunshine position:
Motor running time:
Ventilation position:
Blinds mode:
Auto tilt to:
Auto tilt after:
Standard slat position:
Motor dead time:
Jog mode:
50 x 50 x 12 mm (according to DIN 49075)
230 V / 50 Hz; 230 V / 60 Hz
8 (4) A µ (Type 1B)
< 0.4 W
2 (E1 and E2)
1.5 mm²
32 mm
0 to 40°C
permanent
II (only for use in dry areas)
434.5 MHz
max. 10 mW
indoors approx. 30 m * / outdoors approx. 100 m
* depending on the building structure
On
On
Off
Off
Off
50 %
150 seconds
Off / 80 %
Off, tilting time: = 1.50 seconds
- Sunshine position:
- Ventilation position:
- Moving to a target position:
- Manual stop in direction "Down"
0 %
Off
Off
EN
Off
Off
On
On
39