TEC Series v 3.2X
ENTRANCE X UNLOCK TONE
The Entrance X tone refers to the Touch-Tone™ number from
a telephone that must be pressed to energize the door control
relay. This relay will be energized for whatever length of time
was selected (door open time). Rotary or pulse type
telephones must dial any number "6" or greater to energize the door control relay. This will energize
only the primary door control relay. To change the number from the default setting of 6 to another
number, press "2" from the Entrance 1 Control menu. Select the new number (from 1 -9) and press
the "*" key. You will be returned to the Entry Control menu.
NOTE: SELECTING A "0" DISABLES ENTRANCE 1 UNLOCK TONE FEATURE.
ENTRANCE X AUTO GROUP
The Entrance X Auto Group refers to the group of Access
levels and time zones that allow the entrance to automatically open
on given days for the hours that match the time zone programmed.
. To change the number from the default setting of 0 to another
number, press "3" from the ENT 1 Control menu. Select the new number (from 0 - 9) and press the "*"
key. You will be returned to the Entry Control menu. SELECTING A "0" DISABLES THE AUTO
GROUP FUNCTION. Selecting a number from 1 - 9 allows that number to automatically open the
door on the days and times set for that group.
NOTE: AUTOMATIC UNLOCK/RE-LOCK (AUTO GROUP) OVERRIDES ANY OTHER LATCH
CONTROL.
ENTRANCE X LATCH TONE
The Entrance X Auto Group refers to the group of Access levels and
time zones that allow the entrance to automatically open on given days
for the hours that match the time zone programmed. . To change the number from the default setting
of 0 to another number, press "3" from the ENT 1 Control menu. Select the new number (from 0 - 9)
and press the "*" key. You will be returned to the Entry Control menu. SELECTING A "0"
DISABLES THE AUTO GROUP FUNCTION. Selecting a number from 1 - 9 allows that number to
automatically open the door on the days and times set for that group.
NOTE: IF ENT X TONE AND ENT X LATCH ARE THE SAME NUMBER, THE ENT X RELAY WILL NOT
LATCH OR TIME OUT. IT WILL ENERGIZE BRIEFLY, AND THEN DE-ENERGIZE.
ENTRANCE X AJAR TIME
Press "5" from the Entry Control menu to set the time the entrance
remains open after the open relay returns with this entrance. Present with
2 Entrance units installed with this TEC system. Also in the first two
entrances in a four entrance system when the alarm function is turned off
by setting alarm time to zero. Default is 0 (Off)
ENT X UNLOCK
TONE = 6
ENT X
AUTO GROUP = 0
ENT X
LATCH TONE = 0
ENT X
AJAR TIME = 20
Page 33
Need help?
Do you have a question about the TEC Series and is the answer not in the manual?
Questions and answers
How to change a listed resident's phone number
To change a listed resident's phone number in the Select Engineered Systems TEC Series, you need the Manager's Password. The first three digits of the Program Password serve as the Manager's Password. Once you have access, follow these steps:
1. Enter the Communications Setup menu.
2. Use the Manager's Password to access the settings that allow phone number changes.
3. Locate the option to edit resident details, including phone numbers.
4. Input the new phone number.
5. Confirm the change by pressing the "Enter" key.
This updates the resident's phone number in the system.
This answer is automatically generated