4 Image Acquisition

4.2.4 Acquisition End Trigger

The acquisition end trigger can be used to control the acquisition end procedure. The main
property of this trigger is the trigger mode. It can be set to on or off:
Acquisition End Trigger Mode = on When the acquisition status is "Acquisition Active", it goes
to "Acquisition Trigger Wait" as soon as an acquisition end trigger has been received. The
camera stops capturing images and waits until an acquisition start trigger has been issued
again.
Acquisition End Trigger Mode = off The acquisition end triggers are ignored and the
acquisition status remains active until an acquisition stop command has been executed or
the certain amount of frames has been captured, depending on the acquisition mode
parameter (see Section 4.2.1)

4.2.5 Acquisition Control Output Signals

The acquisition control block has the following output signals:
Acquisition Trigger Wait An asserted acquisition trigger wait indicates, that the acquisition
control is waiting for an acquisition start trigger (see Section 4.2.3).
Acquisition Active Acquisition active is a status signal, which is asserted, when the acquisition
has been started and deasserted, when the acquisition is stopped.
Acquisition Start The acquisition start is an event, which is generated, when the acquisition is
started.
Acquisition End The acquisition end is an event, which is generated, when the acquisition is
stopped.
Acquisition Trigger The acquisition trigger is an event, which is generated, when the
acquisition is started by the acquisition start trigger (see Section 4.2.3).
Acquisition trigger wait and acquisition active status signal are routed to the I/O control block
and can there be selected for output on the physical output line or on one of the available leds
(see Chapter 7). Acquisition start, acquisition end and acquisition trigger event can be used to
trigger or to control other function in the camera, like counter or timer.