Advanced Programming Mode
In advanced programming mode, all Matrix converter constants can be monitored and set.
Constants can be changed from the setting displays. Use the Increment, Decrement, and Shift/RESET Keys to
change the frequency. The user constant will be written and the monitor display will be returned to when the
DATA/ENTER Key is pressed after changing the setting.
Refer to Chapter 5 User Constants for details on the constants.
Example Operations
Key operations in advanced programming mode are shown in the following figure.
-8
3
Mode Selection Display
DATA
-ADV-
-ADV-
ENTER
MxC * MODE sel *
Initialization
A1
Programming
Access Level
ESC
MENU
-ADV-
-A TUNE-
Initialization
MxC * MODE sel *
A1
Control Method
Tuning Mode
MENU
MxC * MODE sel *
Fault History
-ADV-
Torque Limit
MENU
L7
-DRIVE-
Torq Limit Fwd
MxC * MODE sel **
-ADV-
Operation
Torque Limit
MENU
L7
Torq Lmt Rev Rgn
-QUICK-
MxC * MODE sel *
Quick Setting
MENU
Fig 3.5 Operations in Advanced Programming Mode
Monitor Display
1
A
B
-ADV-
RESET
Access Level
A1-
01
-01=2
(0 to 9999)
"2"
ESC
-ADV-
RESET
Control Method
A1-
02
=3
-02=3
*3*
IM VEC. With PG
"3"
ESC
1
3
-ADV-
RESET
Torq Limit Fwd
L7-
01
=200%
-01=150%
(0 to 300)
"150%"
ESC
-ADV-
RESET
Torq Lmt Rev Rgn
L7-
04
=150%
-04=150%
(0 to 300)
"150%"
ESC
A
B
3
Setting Display
DATA
2
ENTER
-ADV-
Access Level
A1-01=
0
002
=2
(0 to 9999)
"2"
ESC
DATA
-ADV-
ENTER
Control Method
A1-02=
3
*3*
*3*
IM VEC. PG-Less
"0"
ESC
2
DATA
4
ENTER
-ADV-
Torq Limit Fwd
L7-01=
1
50%
(0 to 300)
"150%"
ESC
DATA
-ADV-
ENTER
Torq Lmt Rev Rgn
L7-04=
1
50%
(0 to 300)
"150%"
ESC
4