Programming
Adjective/Noun
INPUT ZONE #
1=ADJECTIVE/NOUN
2=DESCRIPTION

Edit Input Zone Screen #5
Pressing 1 while viewing the Adjective/Noun Screen will cause the following screen(s) to be displayed. Note that the keyboard down
arrow key must be pressed to see all the Adjective screens. Press the number corresponding to the adjective that is to be used as a
descriptor for the location of the detector currently being programmed. When an adjective has been selected, it will appear at the top of
the display as indicated by the asterisks.

1=NORTH
2=SOUTH
3=EAST
Adjective Screen #1

1=3RD
2=4TH
3=5TH
Adjective Screen #5
1=STANDARD ADJECTIVE
2=STANDARD NOUN
3=CUSTOM ADJECTIVE
4=CUSTOM NOUN
Adjective/Noun Screen

1=BASEMENT
2=BOILER RM
3=CLASSROOM
Noun Screen #1

1=KITCHEN
2=LOBBY
3=OFFICE
Noun Screen #5
1=STANDARD ADJECTIVE
2=STANDARD NOUN
3=CUSTOM ADJECTIVE
4=CUSTOM NOUN
Adjective/Noun Screen
62
The Adjective/Noun selection allows the programmer to enter specific descriptors about the detector cur-
rently being programmed. Pressing 1 while viewing Edit Input Zone Screen #4 will cause the following
screen to be displayed:
1=STANDARD ADJECTIVE
2=STANDARD NOUN
3=CUSTOM ADJECTIVE
4=CUSTOM NOUN
Adjective/Noun Screen

1=WEST
2=FRONT
3=CENTER
Adjective Screen #2

1=FLOOR1
2=FLOOR2
3=FLOOR3
Adjective Screen #6
Pressing 2 while viewing the Adjective/Noun Screen will cause the following screen(s) to be displayed.
Note that the keyboard down arrow key must be pressed to see all the Noun screens. Press the number cor-
responding to the noun that is to be used as a descriptor for the location of the detector currently being pro-
grammed. When a noun has been selected, it will appear at the top of the display as indicated by the
asterisks.

1=CLOSET
2=CORRIDOR
3=ELECTRIC RM
Noun Screen #2

1=PATIENT
2=RESTROOM
3=ROOM
Noun Screen #6
Pressing 3 or 4 while viewing the Adjective/Noun Screen will display screens similar to the previous
Adjective and Noun Screens. The new screens will list custom Adjectives and Nouns which have been pro-
grammed into the control panel by the user utilizing the PK-CD programming kit. These descriptors are
selected as described in the previous sections.

1=REAR
2=UPPER
3=LOWER
Adjective Screen #3

1=FLOOR4
2=FLOOR5
3=ROOM
Adjective Screen #7

1=ELEVATOR
2=ENTRANCE
3=FLOOR
Noun Screen #3

1=STAIRWAY
2=STOREROOM
3=WING
Noun Screen #7
SFP-5UD & SFP-10UD Series Manual— P/N 52879:C6 6/12/2018
Master Programming Level

1=MAIN
2=FIRST
3=2ND
Adjective Screen #4

1=GARAGE
2=HALLWAY
3=HVAC RM
Noun Screen #4

1=ZONE
Noun Screen #8