Cage Weigh System - nifty Heightrider HYBRID Series Operating/Safety Instructions Manual

Table of Contents

Advertisement

4.5

CAGE WEIGH SYSTEM

4.5.1
LOAD CELL VERSION
The Niftylift HR15/17 is fitted with an electronic load cell. This load cell is a moment-independent,
redundant design. This means that independent of the load position inside the machine cage, the actual
load is measured and if pre-configured limit values are exceeded, warnings will be activated.
"Redundant design" means that the load cell design incorporates dual channels that monitor each
other. The design of the unit meets the requirements of both EN280 and EN954-1 class III.
The current load in the cage is displayed on the digital display unit as a percentage of SWL. Please
refer to Section 4.3.2.
4.5.2
CALIBRATION, INSPECTION AND MAINTENANCE
Calibration, maintenance and repair of the Niftylift HR15/17 cage load cell requires specialist
knowledge and equipment. For this reason, no part of the Niftylift HR17 cage-weigh system can
be adjusted, repaired or inspected by the operator.
All enquiries relating to calibration, inspection or maintenance should be directed to Niftylift or one of
their approved dealers. Contact details are listed in Section 1.3.