nifty Heightrider HYBRID Series Operating/Safety Instructions Manual page 47

Table of Contents

Advertisement

Appendix A
Code
00
Sounder Error
01
Base Green Button, Bulb Error
02
Drive Enable Relay Error
03
Elevated Drive Solenoid Error
04
Auxiliary Descent Error
Machine Enable Relay 1
05
Error
Machine Enable Relay 2
06
Error
07
Horn Error
Base Angle X Channel 1
08
Error
Base Angle X Channel 2
09
Error
Base Angle Y Channel 1
10
Error
Base Angle Y Channel 2
11
Error
12
Fuel Sender Error
13
Base Green Button Error
14
Booms Down Switch Error
15
Machine Enable OK1 Error
English/USA – 04/14
Original instructions
Fault
Open circuit or short circuit of
the base sounder
Open circuit or short circuit of
the base green button bulb
Open circuit or short circuit of
the drive enable relay coil
Open circuit or short circuit of
the elevated drive solenoid
Open circuit or short circuit of
the auxiliary descent contactor
Open circuit or short circuit of
the machine enable relay1 coil
Open circuit or short circuit of
the machine enable relay2 coil
Open circuit or short circuit of
the horn
Error of the corresponding
analogue input during PLC start
up check
Error of the corresponding
analogue input during PLC start
up check
Error of the corresponding
analogue input during PLC start
up check
Error of the corresponding
analogue input during PLC start
up check
Error of the corresponding
analogue input during PLC start
up check
Error of the corresponding
digital input during PLC start up
check
Error of the corresponding
digital input during PLC start up
check
Error of the corresponding
digital input during PLC start up
check
Operating & Safety Instructions
Description
Check wiring to the base sounder
Check bulb is fitted
Check wiring to the base green
button bulb
Check wiring to the drive enable relay
coil on the PCB
Check wiring to the elevated drive
solenoid
Check wiring to the auxiliary descent
contactor
Check wiring to the machine enable
relay1 coil on the PCB
Check wiring to the machine enable
relay2 coil on the PCB
Check wiring to the horn
Check all connections to the tilt sensor
- Reset power
Check all connections to the tilt sensor
- Reset power
Check all connections to the tilt sensor
- Reset power
Check all connections to the tilt sensor
- Reset power
Check all connections to the fuel
sender
- Reset power
Check wiring from the base green
button
- Reset power
Check wiring from the booms down
switch (Normally Closed)
- Reset power
Check wiring from the machine enable
relay1 normally closed contact
- Reset power
Height Rider/SP Series
Action
45