nifty Heightrider HYBRID Series Operating/Safety Instructions Manual page 27

Table of Contents

Advertisement

Base Levers
1
1 Operates Platform Levelling
2 Operates the Flyboom
3 Operates Telescoping
4 Operates the Link Booms
5 Operates the Upper Boom
6 Operates Swing
7 Operates Front Wheel Steer
4.2.2
OPERATION
ALWAYS ALLOW THE ENGINE TO WARM UP BEFORE OPERATING
ALL MODELS
1)
Ensure all red emergency stops are out.
2)
Turn key switch at ground control station to Ground (Single turn clockwise).
3)
For Battery powered operation, go to step 7).
4)
For Diesel powered operation, go to step 5).
DIESEL ENGINE
5)
COLD ENGINE: - turn the Diesel Glow/Start selector to the Glow position (anti-clockwise). This
engages the glow plug pre-heat system. Hold for 5-10 seconds then turn the key to the Start
position (fully clockwise) and the engine will fire.
6)
WARM ENGINE: - turn the Diesel Glow/Start selector to the Start position (clockwise) and the
engine will fire.
Note: Unless the diesel engine is running, the HR15/17 Hybrid will automatically default to the
electrical power source (battery).
English/USA – 04/14
Original instructions
2
3
Forward for Up
Up for Up
Up for Out
Up for Up
Up for Up
Up for Right
Forward for Right
Height Rider/SP Series
Operating & Safety Instructions
4
5
Backward for Down
Down for Down
Down for In
Down for Down
Down for Down
Down for Left
Backward for Left
6
7
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents