nifty Heightrider HYBRID Series Operating/Safety Instructions Manual page 48

Table of Contents

Advertisement

Height Rider/SP Series
Operating & Safety Instructions
Code
16
Debug Error
Key switch Base Switch
17
Error
18
Base ERROR_IO
19
Base ERROR_ANALOG
Base
20
ERROR_OUTPUTBLANKING
Axiomatic Valve Controller
21
off the CANBus
22
Screen off the CANBus
23
Joystick off the CANBus
Chassis Node off the CANBus
24
(Hybrid only)
Motor / Engine Controller off
25
the CANBus
Motor Controller Error
26
(Hybrid only)
46
Fault
Error of the corresponding
digital input during PLC start
up check
Error of the corresponding
digital input during PLC start
up check
Error on one of the inputs or
outputs of the base PLC
Error on one of the analogue
inputs to the base PLC
Error on one of the safety
outputs of the base PLC
The base PLC is not receiving
the valve controller's 'present'
signal
The base PLC is not receiving
the screen's 'present' signal
The base PLC is not receiving
the joystick's 'present' signal
The base PLC is not receiving
the chassis node's 'present'
signal
The base PLC is not receiving
the motor controller's 'present'
signal (Hybrid)
The base PLC is not receiving
the engine node 'present'
signal (Diesel)
The motor controller has
diagnosed an internal fault
Description
Check wiring from the debug core of the
programming port
- Reset power
Check wiring from the 'base' side of the
key switch
- Reset power
Check screen for further fault codes
- Diagnose further using the service tool
Check screen for further fault codes
- Diagnose further using the service tool
Check all connections to the relays on
the base PCB and to the elevated drive
solenoid
Check the power supply to the
Axiomatic controller
Check the CANBus connections from
the base box to the Axiomatic controller
Check the power supply to the screen
Check the CANBus connections from
the cage panel to the screen
Check the power supply to the joystick
Check the CANBus connections from
the cage panel to the joystick
Check the power supply to the chassis
node
Check the CANBus connections from
the base box to the chassis node
Check address dials are set correctly
Check the power supply to the motor
controller (Hybrid) or the engine node
(Diesel)
Check the CANBus connections from
the base box to the motor controller
(Hybrid) or the engine node (Diesel)
Diagnose further using the service tool
Use the LEDs on the motor controller to
ascertain the fault code(s)
(Red and Orange LEDs flash alternately)
1 red is followed by the first digit of the
code
2 reds is followed by the second digit of
the code
Action
English/USA – 04/14
Original instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents