WEG Drive Scan Manual page 45

Low voltage devices
Hide thumbs Also See for Drive Scan:
Table of Contents

Advertisement

CONNECTING A DEVICE TO THE DRIVE SCAN
5.7.3.1 Attributes Cyclically Monitored by the SRW01
Parameter
P002
P003
P004
P006
P008
P009
P010
P011
P014
P016
P020
P030
P031
P032
5
P033
P034
P035
P036
P037
P042
P043
P044
P050
P051
P052
P053
P060
P061
P062
P063
P064
P065
P066
P067
P068
P069
P070
P071 a P073
P075 a P077
P082
P100
P101
P102
P103
P104
P105
P106
P107
P110 a P111
P115 a P116
Low Voltage Devices | 5-26
Description
Current (%)
True RMS current
True RMS line voltage
Relay status
Power factor
Motor reactive power
Motor active power
Motor apparent power
Last fault
Current error
PTC value (ohms)
R phase true RMS current
S phase true RMS current
T phase true RMS current
L1-L2 line voltage
L2-L3 line voltage
L3-L1 line voltage
Earth leakage current (%)
True RMS earth leakage current
Energized hours
Motor on hours
kWh counter
Thermal protection
Current imblance level
Earth fault imbalance
Voltage imbalance level
Total starts number
Overload trips
Current imbalance trips
Earth fault trips
Phase fault trips (current)
Overcurrent trips
Undercurrent trips
Phase out of range trips
PTC trips
Earth leakage trips
External fault trips
Trip 1 to 3 status
Alarm 1 to 3 status
Total trips
Voltage imbalance trips
Out of phase trips
Overvoltage trips
Undervoltage trips
Underpower trips
Overpower trips
Power underfactor trips
Power overfactor trips
Trip 4 to 5 status
Alarm 4 to 5 status
Atributo
Acquisition type
ratedCurrent
Last value
motorCurrent
Valor médio
lineVoltage
Last value
status
Last value
powerFactor
Valor médio
reactivePower
Last value
outputPower
Valor médio
apparentPower
Last value
lastFault
Last value
currentError
Last value
ptcValue
Last value
phaseCurrentR
Last value
phaseCurrentS
Last value
phaseCurrentT
Last value
lineVoltageRs
Last value
lineVoltageSt
Last value
lineVoltageTr
Last value
earthLeakage
Last value
eathLeakageCurrent
Last value
energizedHours
Last value
motorOnHours
Last value
energyCounter
Last value
thermalProtection
Last value
currentUnbalance
Last value
earthFault
Last value
voltageUnbalance
Last value
startsNumber
Last value
overloadTrips
Last value
currentUnbalanceTrips
Last value
earthFaultTrips
Last value
currentPhaseFaultTrips
Last value
overcurrentTrips
Last value
undercurrentTrips
Last value
outOfPhaseTrips
Last value
ptcTrips
Last value
earthLeakageTrips
Last value
externalFaultTrips
Last value
tripStatus1 a tripStatus3
Last value
alarmStatus1
Last value
totalTrips
Last value
voltageUnbalanceTrips
Last value
outOfPhaseTrips
Last value
overvoltageTrips
Last value
undervoltageTrips
Last value
underpowerTrips
Last value
overpowerTrips
Last value
powerUnderfactorTrips
Last value
powerOverfactorTrips
Last value
tripStatus4 a tripStatus5
Last value
alarmStatus1 a alarmStatus5
Last value
Class
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
diagnostic
diagnostic
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
diagnostic
diagnostic
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
status
status
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
measurement
status
status