Slave 10
RS-485 Network
Modbus-RTU Protocol
WARNING!
The Drive Scan can only be connected to the internet using the Ethernet port GbE0 if it does not
have a proxy.

5.3.3 MONITORING

The Drive Scan continuously monitors the CFW100 parameters specified in
Monitored by the CFW100 on page 5-10
After a cycle of all these readings, as well as of the other assets connected to the Drive Scan, a new reading cycle
starts automatically.
The parameters read are transformed into attributes, which can be:
Only at initialization;
Last value read;
Average value;
Minimum value;
Maximum value.
Every 5 minutes, the Drive Scan publishes the attributes to the WEG Fleet Management platform.
In case of an internet connection failure, the Drive Scan stores the data for up to 30 days in the internal memory,
publishing it to the MFM when the connection is reestablished.
In case the CFW100 fails, the Drive Scan automatically publishes the parameters specified in
Attributes Monitored in Events by the CFW100 on page 5-10
normal cyclical period of publication.
Slave 2
Slave 1
Drive Scan
Figure 5.6: Possible connections to the CFW100
.
CONNECTING A DEVICE TO THE DRIVE SCAN
Cloud
Section 5.3.3.1 Attributes Cyclically
asynchronously, that is, without waiting for the
Low Voltage Devices | 5-9
Motion Fleet Mangement
Section 5.3.3.2
5