3 Grid wire of the charge unit and grid zener diode 02V1

Put the grid zener diode 02V1 into the left housing.
1
protrusion
2.5 mm max.
left housing
Put the anode through the hole in the protrusion.
2
Put the cathode through the hole in the side cover and fold it inwards
3
Cut both ends. (max. length of the ends 2.5 mm).
4
Place the charging unit as indicated in the figure.
5
left housing
approx.
45 °
screw
Position the left housing at an angle of approx. 45 ° by blocking the left hous-
6
ing with the screw.
Insert the grid wire through the hole in the protrusion of the left housing.
7
Wrap the grid wire 5 times around the protrusion of the left housing.