11.7

Approvals data

Application type
Non-hazardous
General purpose
Radio
Hazardous
Intrinsically safe
(Page 41)
11.8

Programmer data - 7ML1930-1BK

Siemens Infrared IS (Intrinsically Safe) Handheld Programmer for hazardous and all other
locations (battery is non-replaceable).
Approvals
Ambient temperature
Interface
Power
Weight
Color
Part number
SITRANS LR260 with mA/HART
Operating Instructions, 11/2019, A5E32337683-AD
LR260 version
CSA
C
Europe (RED), FCC, Industry Canada
ATEX II 1G Ex ia IIC T4 Ga
ATEX II 1D, 1/2D, 2D Ex ta IIIC 100°C Da
ATEX II 3G Ex nA II T4 Gc
IECEx SIR 11.0153X Ex ia IIC T4 Ga, Ex ta IIIC T100
°C Da
IECEx SIR 07.0090X Ex ia IIC T4 Ga, Ex ta IIIC T100
°C Da
FM/CSA
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Class III T4
FM/CSA
Class I, Div 2, Groups A, B, C, D T5
INMETRO: DNV 12.0081 X
Ex ia IIC T4 Ga
Ex ia ta IIIC T100 °C Da
-40 °C ≤ Ta ≤ +80 °C
IP67/IP68
CE
FM/CSA Class I, II, III, Div. 1, Gr. A to G T6
ATEX 1 GD Ex ia op is IIC T4 Ga
Ex ia op is IIIC T135°C Da
IECEx Ex ia op is IIC T4 Ga
Ex ia op is IIIC T135°C Da
INMETRO Ex ia op is IIC T4 Ga
Ex ia op is IIIC T135°C Da
−20 to +50 °C (−5 to +122 °F)
proprietary infrared pulse signal
3 V non-replaceable lithium battery
150 g (0.3 lb)
black
7ML1930-1BK
Approval rating
, FM, CE, RCM
US
11.8 Programmer data - 7ML1930-1BK
N. America, Eu‐
rope
Europe
International
US/Canada
Brazil
Technical data
Valid for: