To acknowledge an alert via SIMATIC PDM:
1. Open the menu View – Device Status and click on the Maintenance tab.
2. In the Sensor Lifetime section click on Acknowledge Warnings.
To acknowledge an alert via the handheld programmer:
1. Press RIGHT arrow twice to open parameter view and activate Edit Mode.
2. Press RIGHT arrow to acknowledge the alert.
8.7

Service (4.)

8.7.1

Device Reset (4.1.)

Resets all parameter to factory defaults, with the following exceptions:
● The Lock and Unlock values are not reset.
● The learned TVT curve is not lost.
● The device address is not reset.
● In PDM, the Identification parameters are not reset.
Note
Following a reset to factory defaults, complete reprogramming is required.
To perform a reset to factory defaults via SIMATIC PDM, open the menu Device – Device Reset
and click on Factory Defaults.
8.7.2

Manufacture Date (MANUF. DATE) (4.2.)

The date of manufacture of the SITRANS LR260 (yy mm dd).
8.7.3

LCD Fast Mode (4.3.)

Note
Affects Measurement mode only: has no effect on Navigation mode.
SITRANS LR260 with mA/HART
Operating Instructions, 11/2019, A5E32337683-AD
Options
*
Idle or Done (Return to previous menu)
Factory Defaults
Parameter reference