Total Calibration Interval (Total Calib. Intrv.) (4.17.6.); Maintenance Status (Maint. Stat.) (4.17.7.); Acknowledge Status (Ack. Status) (4.17.8.); Acknowledge (Ack.) (4.17.9.) - Siemens SITRANS LR260 Operating Instructions Manual

Radar transmitters ma/hart
Hide thumbs Also See for SITRANS LR260:
Table of Contents

Advertisement

Parameter reference
8.7 Service (4.)
8.7.24

Total Calibration Interval (TOTAL CALIB. INTRV.) (4.17.6.)

Note
The device always operates in years. Changing the units affects only the parameter view of the
Calibration Interval parameters in SIMATIC PDM.
User-configurable recommended time between product calibrations.
Units are selectable only via SIMATIC PDM.
1)
8.7.25

Maintenance Status (MAINT. STAT.) (4.17.7.)

Read only. Displays the status of the Maintenance Limits.
In SIMATIC PDM, open the menu View – Device Status, click on the Maintenance tab and
check the Calibration Schedule Status window.
8.7.26

Acknowledge Status (ACK. STATUS) (4.17.8.)

Read only. Acknowledges the status of the Maintenance limits.
In SIMATIC PDM, open the menu View – Device Status, click on the Maintenance tab and
check the Calibration Schedule Status window.
8.7.27

Acknowledge (ACK.) (4.17.9.)

Acknowledges the current limit status.
To acknowledge an alert via SIMATIC PDM:
1. Open the menu View – Device Status and click on the Maintenance tab.
2. In the Calibration Schedule Status section, click on Acknowledge Warnings.
To acknowledge an alert via the handheld programmer:
1. Press RIGHT arrow twice to open parameter view and activate Edit Mode.
2. Press RIGHT arrow to acknowledge the alert.
110
Units
1)
Values
Range: 0 to 20 years
Default: 1 year
: hours, days, years
Operating Instructions, 11/2019, A5E32337683-AD
SITRANS LR260 with mA/HART