BALANCE
Functions
BALANCE
Set
BALANCE?
Get
Description
Set the balance level
Set
Get
Get the current balance level
Response
~nn@BALANCESPout_channel,balance_levelCR LF
Parameters
out_channel – output number: 1-16 (varies according to installed output cards, see
Numbering
on page 12)
balance_level – balance level in Kramer units: 0-100, ++ (increase current value), -- (decrease
current value)
Response Trigger
Notes
A minus sign precedes negative values
K-Config Example
Set the balance level of output 5 to 50:
"#BALANCE 5,50",0x0D
Increase the balance level of output 5 by 1 unit:
"#BALANCE 5,++",0x0D
BASS
Functions
BASS
Set
BASS?
Get
Description
Set the audio bass level
Set
Get
Get the current audio bass level
Response
~nn@BASSSPchannel,bass_levelCR LF
Parameters
channel – output number: 1-16 (varies according to installed output cards, see
Numbering
on page 12)
bass_level – bass level in Kramer units: 0-15, ++ (increase current value), -- (decrease current
value)
Response Trigger
Notes
A minus sign precedes negative values
K-Config Example
Set the bass level of output 10 to 4:
"#BASS 10,4",0x0D
Decrease the bass level of output 5 by 1 unit:
"#BASS 5,--",0x0D
VS-1616DN-EM – Protocol 3000
Permission
End User
End User
Syntax
#BALANCESPout_channel,balance_levelCR
#BALANCE?SPout_channelCR
Permission
End User
End User
Syntax
#BASSSPchannel,bass_levelCR
#BASS?SPchannelCR
Kramer Electronics Ltd.
Transparency
Public
Public
Port
Transparency
Public
Public
Port
148

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS-1616DN-EM and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents