TM
R/W NV Format Units
• • 40154
R
NV
ULong
• • 40155
• • 40156
R
NV
ULong
• • 40157
• • 40158
R
NV
ULong
• • 40159
• • 40160
R
NV
ULong
• • 40161
• • 40162
R
NV
ULong
• • 40163
• • 40164
R
NV
ULong
• • 40165
• • 40166
R
NV
ULong
• • 40167
• • 40168
R
NV
ULong
• • 40169
• • 40170
R
NV
ULong
• • 40171
• • 40172
R
NV
ULong
• • 40173
• • 40174
R
NV
UInt
• • 40175
R
NV
ULong
• • 40176
• • 40177
R
NV
UInt
• • 40178
R
NV
UInt
ZL0067-0B
PAGE 28
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
E51
Scale
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
VAR-
M_Energy_VAR_SF
hours
SF
1
Flags
©2011 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Range
SunSpec Name
M_Import_VARh_
0x0 to 0xFFFFFFFF
Q2B
M_Import_VARh_
0x0 to 0xFFFFFFFF
Q2C
0x0 to 0xFFFFFFFF M_Export_VARh_Q3 Quadrant 3: Total Exported Reactive Energy
M_Export_VARh_
0x0 to 0xFFFFFFFF
Q3A
M_Export_VARh_
0x0 to 0xFFFFFFFF
Q3B
M_Export_VARh_
0x0 to 0xFFFFFFFF
Q3C
0x0 to 0xFFFFFFFF M_Export_VARh_Q4 Quadrant 4: Total Exported Reactive Energy
M_Export_VARh_
0x0 to 0xFFFFFFFF
Q4A
M_Export_VARh_
0x0 to 0xFFFFFFFF
Q4B
M_Export_VARh_
0x0 to 0xFFFFFFFF
Q4C
M_Energy_VA_SF
Events
M_Events
Event
M_EVENT_Power_Failure
M_EVENT_Under_Voltage
M_EVENT_Low_PF
M_EVENT_Over_Current
M_EVENT_Over_Voltage
M_EVENT_Missing_Sensor 0x00000080
M_EVENT_Reserved1-8
M_EVENT_OEM1-15
End of SunSpec Block
0xFFFF
0x0000
INSTALLATION GUIDE
Description
Phase B - Quadrant 2: Total Imported Reactive Energy
Phase C - Quadrant 2: Total Imported Reactive Energy
Phase A - Quadrant 3: Total Exported Reactive Energy
Phase B - Quadrant 3: Total Exported Reactive Energy
Phase C - Quadrant 3: Total Exported Reactive Energy
Phase A - Quadrant 4: Total Exported Reactive Energy
Phase B - Quadrant 4: Total Exported Reactive Energy
Phase C - Quadrant 4: Total Exported Reactive Energy
Reactive Energy Scale Factor
Bit Map. See M_EVENT_flags. 0 = no event
Bit
0x00000004
Loss of power or phase
0x00000008
Voltage below threshold (phase loss)
0x00000010
Power factor below threshold (can
indicate misassociated voltage and
current inputs in 3-phase systems)
0x00000020
Current input over threshold (out of
measurement range)
0x00000040
Voltage input over threshold (out of
measurement range)
Sensor not connected (not
supported)
0x00000100 to
Reserved for future SunSpec use
0x00008000
0x7FFF000
Reserved for OEMs (not used)
C_SunSpec_DID = 0xFFFF
Uniquely identifies this as the last SunSpec block
C_SunSpec_Length = 0
Last block has no length
Description
03112
Need help?
Do you have a question about the ConnectPort X4 IA and is the answer not in the manual?