Digi ConnectPort X4 IA Quick Start Manual page 57

Hide thumbs Also See for ConnectPort X4 IA:
Table of Contents

Advertisement

TM
R/W NV Format
• 169
R/W NV
UInt
• 170
R/W NV
UInt
• 171
R/W NV
UInt
• 172
R/W NV
UInt
• 173
R/W NV
UInt
• 174
R/W NV
UInt
• 175
R/W NV
UInt
• 176
R/W NV
UInt
• 177
R/W NV
UInt
• 178
R/W NV
UInt
• 257/258 R
NV
Float
• 259/260 R
NV
Float
• 261/262 R
Float
• 263/264 R
Float
• 265/266 R
Float
• 267/268 R
Float
• 269/270 R
Float
• 271/272 R
NV
Float
• 273/274 R
NV
Float
• 275/276 R
NV
Float
• 277/278 R
Float
• 279/280 R
Float
• 281/282 R
Float
• 283/284 R
Float
• 285/286 R
Float
• 287/288 R
Float
• 289/290 R
Float
• 291/292 R
Float
• 293/294 R
Float
• 295/296 R
Float
• 297/298 R
Float
ZL0067-0B
PAGE 23
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
E51
Units Scale
Range
1-42,
146,
155-157,
257-336
Floating Point Data: Summary of Active Phases
kWh
kWh
kWh
kVARh
kVARh
kVARh
kVARh
kVAh
kVAh
kVAh
kW
kVAR
kVA
Ratio
0.0-1.0
Volt
Volt
Amp
Hz
45.0-65.0
kW
kVAR
kVA
©2011 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Log Register 1 –
Default is 3 (Import Real
Energy MSR)
Log Register 2 –
Default is 4 (Import Real
Energy LSR)
Log Register 3 –
Default is 5 (Export Real
Energy MSR)
Log Register 4 –
Default is 6 (Export Real
Energy LSR)
Log Register Selection – Write the number of the 16 bit register to be
Log Register 5 –
logged. To log a 32 bit value (such as accumulators and floating point
Default is 29 (Real Demand)
values) two log registers must be used, one each for the most and least
Log Register 6 –
significant register (MSR & LSR).
Default is 30 (Reactive
Demand)
Log Register 7 –
Default is 31 (Apparent
Demand)
Log Register 8 –
Default is 155 (Month/Day)
Log Register 9 –
Default is 156 (Year/Hour)
Log Register 10 –
Default is 157 (Minutes/
Seconds)
Accumulated Real Energy: Net (Import - Export)
Real Energy: Quadrants 1 & 4
Import
Real Energy: Quadrants 2 & 3
Export
Reactive Energy: Quadrant 1
Lags Import Real Energy (IEC) Inductive (IEEE)
Reactive Energy: Quadrant 2
Leads Export Real Energy (IEC) Inductive (IEEE)
Reactive Energy: Quadrant 3
Lags Export Real Energy (IEC) Capacitive (IEEE)
Reactive Energy: Quadrant 4
Leads Import Real Energy (IEC) Capacitive (IEEE)
Apparent Energy: Net (Import - Export)
Apparent Energy: Quadrants 1 & 4
Import
Apparent Energy: Quadrants 2 & 3
Export
Total Net Instantaneous Real (P) Power
Total Net Instantaneous Reactive (Q) Power
Total Net Instantaneous Apparent (S) Power
Total Power Factor (Total kW / Total kVA)
Voltage, L-L (U), average of active phases
Voltage, L-N (V), average of active phases
Current, average of active phases
Frequency
Total Real Power Present Demand
Total Reactive Power Present Demand
Total Apparent Power Present Demand
INSTALLATION GUIDE
Description
Accumulated Real Energy
(Ph)
Accumulated Reactive
Energy (Qh):
Quadrants 1+2= Import
Quadrants 3+4= Export
Accumulated Apparent
Energy (Sh): Import and
Export correspond with
Real Energy
Clear via register
129
03112