SunSpec and Modbus
The PV
-100-2 follows the SunSpec standard. Refer to the official SunSpec
MET
specifications for application information. The full register map is listed below. The
PV
-100-2 has the following default communication settings:
MET
Serial/ General
Baud Rate
9600
Parity
None
Stop Bits
1
RS-232
Flow control None
RS-485
2-Wire Half Duplex
Modbus
Device ID
60
Register Map:
Start
End
# Name
0001
0002
2 C_SunSpec_ID
0003
0003
1 C_SunSpec_DID
0004
0004
1 C_SunSpec_Length
0005
0020
16 C-Manufacturer
0021
0036
16 C-Model
0037
0044
8 C-Options
0045
0052
8 C-Version
0053
0068
16 C_Serial Number
0069
0069
1 C_DeviceAddress
0070
0070
1 C_SunSpec_DID
0071
0071
1 C_SunSpec_Length
0072
0072
1 E_BaseMet_Air
Temperature
0073
0073
1 E_BaseMet_Relative
Humidity
0074
0074
1 E_BaseMet_Barometric
_Pressure
0075
0075
1 E_BaseMet_Wind_Spee
d
Scale
Type
Units
Factor
uint32
N/A
N/A
uint16
N/A
N/A
uint16
registers N/A
String(32)
N/A
N/A
String(32)
N/A
N/A
String(16)
N/A
N/A
String(16)
N/A
N/A
String(32)
N/A
N/A
unint16
N/A
N/A
int16
N/A
N/A
int16
N/A
N/A
int16
°C
int16
%
int16
Hpa
int16
m/s
- 10 -
Contents
Description
"SunS"
Well-known value. Uniquely
identifies this as a SunSpec
Modbus Map
0x0001
Well-known value. Uniquely
identifies this as a SunSpec
Common Model block
65
Length of common model block
"Rainwise_Inc" Well-known value
"PVmet-100"
Manuf specific value
"0"
Manuf specific value
"1"
Manuf specific value
"Serial"
Manuf specific value
60
Modbus Id
307
Start of next Device
11
Device Model Block Size
-1
Measured
Ambient Air Temperature
0
N/A
Relative Humidity
0
N/A
Barometric Pressure
0
N/A
Wind Speed