R/W NV Format
• 001
R
NV
SLong
• 002
• 003
R
NV
ULong
• 004
• 005
R
NV
ULong
• 006
• 007
R
NV
ULong
• 008
• 009
R
NV
ULong
• 010
• 011
R
NV
ULong
• 012
• 013
R
NV
ULong
• 014
• 015
R
NV
SLong
• 016
• 017
R
NV
ULong
• 018
• 019
R
NV
ULong
• 020
• 021
R
SInt
• 022
R
SInt
• 023
R
UInt
• 024
R
SInt
• 025
R
UInt
• 026
R
UInt
• 027
R
UInt
• 028
UInt
• 029
R
SInt
• 030
SInt
• 031
R
SInt
• 032
R
NV
SInt
• 033
R
NV
SInt
• 034
R
NV
SInt
• 035
R
NV
SInt
• 036
R
NV
SInt
• 037
R
NV
SInt
• 038
R
UInt
• 039
R
NV
ULong
• 040
• 041
R
NV
ULong
• 042
ZL0067-0B
PAGE 17
Alta Labs, Enercept, Enspector, Hawkeye, Trustat, Veris, and the Veris 'V' logo are trademarks or registered trademarks of Veris Industries, L.L.C. in the USA and/or other countries.
E51
Units Scale
Range
Integer Data: Summary of Active Phases
-2147483647 to
kWh
E
+2147483647
kWh
E
0 to 0xFFFFFFFF
kWh
E
0 to 0xFFFFFFFF
kVARh
E
0 to 0xFFFFFFFF
kVARh
E
0 to 0xFFFFFFFF
kVARh
E
0 to 0xFFFFFFFF
kVARh
E
0 to 0xFFFFFFFF
-2147483647 to
kVAh
E
+2147483647
kVAh
E
0 to 0xFFFFFFFF
kVAh
E
0 to 0xFFFFFFFF
kW
W
-32767 to +32767 Total Instantaneous Real (P) Power
kVAR
W
0 to 32767
kVA
W
0 to 32767
Ratio
0.0001 -10000 to +10000 Total Power Factor (total kW / total kVA)
Volt
V
0 to 32767
Volt
V
0 to 32767
Amp
I
0 to 32767
Hz
0.01
4500 to 6500
kW
W
-32767 to +32767 Total Real Power Present Demand
kVAR
W
-32767 to +32767 Total Reactive Power Present Demand
kVA
W
-32767 to +32767 Total Apparent Power Present Demand
kW
W
-32767 to +32767 Total Real Power Max. Demand
kVAR
W
-32767 to +32767 Total Reactive Power Max. Demand
kVA
W
-32767 to +32767 Total Apparent Power Max. Demand
kW
W
-32767 to +32767 Total Real Power Max. Demand
kVAR
W
-32767 to +32767 Total Reactive Power Max. Demand
kVA
W
-32767 to +32767 Total Apparent Power Max. Demand
0 to 0xFFFFFFFF
0 to 0xFFFFFFFF
©2011 Veris Industries USA 800.354.8556 or +1.503.598.4564 / support@veris.com
Real Energy: Net (Import - Export)
Real Energy: Quadrants 1 & 4
Import
Real Energy: Quadrants 2 & 3
Export
Reactive Energy - Quadrant 1:
Lags Import Real Energy (IEC) Inductive (IEEE)
Reactive Energy - Quadrant 2:
Leads Export Real Energy (IEC) Inductive (IEEE)
Reactive Energy - Quadrant 3:
Lags Export Real Energy (IEC) Capacitive (IEEE)
Reactive Energy - Quadrant 4:
Leads Import Real Energy (IEC) Capacitive (IEEE)
Apparent Energy: Net (Import - Export)
Apparent: Quadrants 1 & 4
Import
Apparent: Quadrants 2 & 3
Export
Total Instantaneous Reactive (Q) Power
Total Instantaneous Apparent (S) Power (vector sum)
Voltage, L-L (U), average of active phases
Voltage, L-N (V), average of active phases
Current, average of active phases
Frequency
Reserved, returns 0x8000 (QNAN)
MSR
Pulse Counter 1
(Import Real Energy)
LSR
MSR
Pulse Counter 2
(Export Real Energy)
LSR
INSTALLATION GUIDE
Description
MSR
LSR
Accumulated
MSR
Real Energy
(Ph)
LSR
MSR
LSR
MSR
LSR
Accumulated
MSR
Reactive
Energy (Qh):
LSR
Quadrants 1 + 2
MSR
= Import
Quadrants 3 + 4
LSR
= Export
MSR
LSR
MSR
Accumulated
Apparent
LSR
Energy (Sh):
MSR
Import and
Export
LSR
correspond
MSR
with Real
Energy
LSR
Import
Export
Contact Closure Counters. Valid for both pulse
inputs and outputs. E51Cx counts are shown
in (). See register 144 - Energy Per Pulse for
the Wh per pulse count.
Clear via reset