New S82K
Minimum Output Current
The minimum output current of the S82K-00727 and S82K-00728 is
restricted by the output voltage and control method.
Note:
All the outputs of the S82K-00727 and S82K-00728 are
controlled by the +V output. If the +V output current falls to
10% or less of the rated output, the - -V output voltage may
drop.
Operating and Storage Environments
Do not use or store the Unit in the following places, otherwise the
Unit may malfunction or the characteristics of the Unit may deterio-
rate.
%
Locations subject to direct sunlight.
%
Locations subject to ambient operating temperatures outside the
range indicated by the derating curve.
%
Locations subject to ambient operating humidity outside the
range of 25% to 85%.
%
Locations subject to condensation as the result of severe
changes in temperature.
%
Locations subject to ambient storage temperatures outside the
range of - -25"C to 65"C.
%
Locations subject to corrosive or flammable gases.
%
Locations subject to dust (especially iron dust) or salts.
%
Locations subject to shock or vibration.
%
Locations subject to exposure to water, oil, or chemicals.