Description Of Potentiometer Jp; Buzzer; Description Of Push Button - Renesas RL78/I1D User Manual

Detector boards kit
Hide thumbs Also See for RL78/I1D:
Table of Contents

Advertisement

DETECT-IT RL78/I1D detector boards kit
Jumper
Status
J1
Closed
Open
J2
Closed
Open
J4
Opened
1-2
2-3
DN_J10
Closed
Open
DN_J14
Closed
Open
In order to start the demonstration of the CO detector, please ensure that this initial configuration is done:
• J1 should be closed
• J2 should be closed
• DN_J10 should be open
• DN_J14 can be closed or opened
5.2.3

Description of Potentiometer JP

Table
Description of potentiometer of CO detector
Potentiometer
Status
JP10
IVREF1
comparator 1
JP11
IVREF0
comparator 0
5.2.4

Buzzer:

The buzzer is used for alarm by the application. It is connected to MCU pin P01/PCLBUZ1
5.2.5

Description of Push Button

The push button is connected MCU pin P137 / INTP0 via R3. It is not used in the current CO detector application.
Table
Description of push button of CO detector
Button
Status
SW1
Un-pressed
Pressed
UM-YDETECT-IT-RL78 V1.30
Function
Power supply of the MCU and others components [MCU, Alarm/buzzer,
AVDD via L1, U1 Vin (optional), pull up resistors, R16/R10 and R13/R19]:
power from battery or power from E1 via CN01-pin 5, CN02-pin 4
Caution : Battery should never be installed when using E1 power supply or
external power supply via CN02/CN01
Current measurement of the MCU and others components [MCU,
Alarm/buzzer, L1and AVDD, U2 Vin (optional), pull up resistors] by
connection of the ampere meter
Power supply of some components [R18, R17, R15, R11, J3] on glass break
detectors board
Current measurement of some components [R18, R17, R15, R11, J3] by
connection of the ampere meter
Normal operation
Optional REGC = 1.8V to AVREFP (with SW change)
Optional AIC1702L-25 output = 2.5V to AVREFP (with SW change)
Use less – no amplification of trans impedance amplifier
May bypass with Resistor to change the Impedance
Filter (R45 & C20 used) between Amp0 Out and Amp0 –
Direct connection to Ground (please check schematics for more details) - no
influence for the CO detector application
R32 is used (please check schematics for more details) - no influence for the
CO detector application
Function
Could be used when J3 is closed (please check schematics for more details).
Could be used when J3 is closed (please check schematics for more details).
Function
INTP0 is High – no operation
INTP0 goes Low – no operation
Kit User Manual
Page 27 of 59

Advertisement

Table of Contents
loading

Table of Contents