Device Management
3.2 Configuring the Device
The serial console port implements RS232 DCE (Data Communication Equipment) on
a DB9 connector. The following is the pin-out for the port:
Figure 3.1
a
Connected internally.
b
Connected internally.
Ethernet Ports
Connect any of the available Ethernet ports on the device to a management
switch and access the RUGGEDCOM RS900W console and Web interfaces via the
device's IP address. The factory default IP address for the RUGGEDCOM RS900W is
https://192.168.0.1.
For more information about available ports, refer to
23)".
3.2
Configuring the Device
Once the device is installed and connected to the network, it must be configured.
All configuration management is done via the RUGGEDCOM RS900W interface.
For more information about configuring the device, refer to the RUGGEDCOM ROS
Configuration Manual associated with the installed software release.
3.3
Resetting the Device
The RUGGEDCOM RS900W can be reset (rebooted) using the RESET button. The
RESET button is recessed and can only be reached using a pin or small screwdriver.
To reset the device, quickly press and release the RESET button with a pin.
22
1
5
9
6
Serial DB9 Console Port
Pin
Name
a
1
Reserved (Do Not Connect)
2
TX
3
RX
a
4
Reserved (Do Not Connect)
5
GND
a
6
Reserved (Do Not Connect)
b
7
Reserved (Do Not Connect)
b
8
Reserved (Do Not Connect)
9
Reserved (Do Not Connect)
"Communication Ports (Page
Installation Manual, 04/2021, C79000-G8976-1028-13
Description
Transmit Data
Receive Data
Signal Ground
RUGGEDCOM RS900W