2.7.2 Connecting Low Dc Power - Siemens SIMATIC NETRUGGEDCOM RS900W Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

3.
4.
2.7.2
Connecting Low DC Power
RUGGEDCOM RS900W's equipped with 24 or 48 V power supply inputs feature
reverse polarity protection and dual power supply inputs allowing the device to
accept redundant connections to a single DC power supply.
To connect a low DC power supply to the device, do the following:
Note
Torque all terminal connections to 0.6 N·m (5 lbf-in).
1.
RUGGEDCOM RS900W
Installation Manual, 04/2021, C79000-G8976-1028-13
2
2
1
3
1
Positive Terminal
1
Negative Terminal
2
Surge Ground Terminal
3
Braided Ground Cable
4
Figure 2.7
Terminal Block Wiring – Dual DC Power Supply Inputs
Connect the negative wire from the power source to the negative/neutral (-/N)
terminal on the terminal block.
Connect the ground wire from the power source to the chassis groun terminal
on the terminal block.
Secure the power terminal block to the device.
Installing the Device
2.7.2 Connecting Low DC Power