Technical Specifications
5.2 Failsafe Alarm Relay Specifications
5.2
Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage
Non-Hazardous Environment
Maximum Switching Voltage
5.3
Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RS900W:
Standard
IEEE 802.3x
IEEE 802.3z
IEEE 802.3ab
IEEE 802.1D
IEEE 802.1Q
IEEE 802.1p
5.4
Copper Ethernet Port Specifications
The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RS900W.
Speed
Connector
Duplex
Cable Type
30
30 VDC
80 VDC
30 VAC
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
10 Mbps
Ports
•
•
•
•
a
10/100Base-TX
RJ45
a
FDX/HDX
b
> CAT 5
Rated
Switching
Current
1 A
1500 V
rms
0.3 A
Rated
Switching
Current
2 A, 60 W
1500 V
rms
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
100 Mbps
1000 Mbps Ports
Ports
•
•
•
•
•
•
•
•
•
•
Isolation
for 1 minute
Isolation
for 1 minute
Notes
Full Duplex Operation
1000Base-LX
1000Base-Tx
MAC Bridges
VLAN (Virtual LAN)
Priority Levels
Installation Manual, 04/2021, C79000-G8976-1028-13
RUGGEDCOM RS900W
Need help?
Do you have a question about the SIMATIC NETRUGGEDCOM RS900W and is the answer not in the manual?