Siemens SIMATIC NETRUGGEDCOM RS900W Installation Manual page 48

Rugged ethernet switches
Table of Contents

Advertisement

61000-4-16
61000-4-17
61000-4-29
IEC 60255-5
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RS900W meets Class 2 requirements for an all-fiber
configuration and Class 1 requirements for copper ports. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Fast Transient
RUGGEDCOM RS900W
Installation Manual, 04/2021, C79000-G8976-1028-13
Test
IEC
Mains Frequency Voltage
IEC
Ripple on DC Power Supply
IEC
Voltage Dips and Interrupts
Dielectric Strength
HV Impulse
Description
ESD
Radiated RFI
Oscillatory
HV Impulse
6.2 EMC and Environmental Type Tests
Description
Signal Ports
DC Power
Ports
DC Power
Ports
DC Power
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Signal Ports
DC Power
Ports
AC Power
Ports
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
Test Levels
1 kV Differential
Mode @ 1 MHz
30 V Continuous
300 V for 1 s
30 V Continuous
300 V for 1 s
10%
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Failsafe Relay Output)
1.5 kV
2 kV
5 kV (Failsafe Relay Output)
5 kV
5 kV
Test Levels
± 8 kV
± 15 kV
35 V/m
± 4 kV @ 2.5 kHz
± 4 kV
± 4 kV
± 4 kV
2.5 kV Common Mode @ 1 MHz
2.5 kV Common and
Differential Mode @ 1 MHz
2.5 kV Common and
Differential Mode @ 1 MHz
5 kV (Failsafe Relay)
Certification
Severity
Levels
4
4
3
 
 
 
 
 
 
 
39

Advertisement

Table of Contents
loading

Table of Contents