Figure 28. Power Xpert Solar Machine-State Transition Diagram; Table 11. Critical Faults: Critical Faults - Eaton Power Xpert Solar 1500 User Manua

Utility-scale photovoltaic inverter
Table of Contents

Advertisement

Troubleshooting

Figure 28. Power Xpert Solar Machine-State Transition Diagram

Table 11. Critical Faults: CRITICAL FAULTS

Critical
Faults
Display Text
CF1
CB1 Fault
CF2
Disconnect 1 Fault
CF3
Disconnect 2 Fault
CF4
Disconnect 3 Fault
DCF7
Disconnect Open
ESTOP
E-Stop Input
FUF1
Fuse Fault 1
FUF2
Fuse Fault 2
46
Power Xpert Solar 1500/1670 kW Inverter MN141001EN—October 2014 www.eaton.com
Description
Circuit Breaker 1 hardware feedback fault
(Wiring Error Detection)
DC DS1 Disconnect hardware feedback fault
(Wiring Error Detection)
DC DS2 Disconnect hardware feedback fault
(Wiring Error Detection)
DC DS3 Disconnect hardware feedback fault
(Wiring Error Detection)
Occurs when a DC Disconnect is manually
opened during operation.
Local E-Stop pushbutton asserted
Filter Capacitor Fuse Fault
Indicates one of the filter-capacitor fuses
failed in Stack 1.
Filter Capacitor Fuse Fault
Indicates one of the filter-capacitor fuses
failed in Stack 2.
Resolution
Following these steps. if fault continues, contact Eaton service
1. Check CB1 wiring
2. Ensure that CB1 is powered
Check DC Disconnect DS1 wiring
Check DC Disconnect DS2 wiring
Check DC Disconnect DS3 wiring
1. Do not open DC disconnects (DS1 DS2 DS3) while running
2. Check DC disconnect shunt-trip wiring.
1. Pull OUT the E-Stop button
Button pulled OUT is the "normal" non-fault position
2. Reset fault via HMI
3. Check E-Stop wiring on the control section cabinet door
The three circuit contacts are of the N.C. (fail-safe) type
Check the 400 A LC filter fuses in Stack 1 (continuity check)
F13 –FSW1 | F14 –FSW2 | F15 –FSW3
Circuits from CAUX2-J3-8 to TB11-7
Check the 400 A LC filter fuses in Stack 2 (continuity check)
F16 –FSW4 | F17 –FSW5 | F18 –FSW6
Circuits from CAUX2-J3-7 to TB11-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power xpert solar 1670

Table of Contents