BAFANG DP C13.CAN User Manual page 13

Table of Contents

Advertisement

Error
Declaration
The protection temperature inside
14
the controller has reached its maxi-
mum protection value
Error with the temperature sensor
15
inside the controller
21
Speed sensor Error
25
Torque signal Error
Speed signal of the torque sensor has
26
an error
27
Overcurrent from controller
30
Communication problem
Brake signal has an error
33
(If brake sensors are fitted)
BF-UM-C-DP C13-EN November 2019
Troubleshooting
1. Turn off the system and let the pedelec cool
down.
2. If the problem persists, please contact your
retailer.
Please contact your retailer.
1. Restart the system
2. Check that the magnet attached to the
spoke is aligned with the speed sensor and
that the distance is between 10 mm and 20
mm.
3. Check that the speed sensor connector is
connected correctly.
4. If the error persists, please contact your
retailer.
1. Check that all connections are connected
correctly.
2. If the error persists, please contact your
retailer.
1.Check the connector from the speed sensor
to make sure it is connected correctly.
2.Check the speed sensor for signs of damage.
3.If the problem persists, please contact your
retailer.
Please contact your retailer.
1. Check all connections are correctly con-
nected.
2. If the error persists, please contact your
retailer.
1. Check all connectors.
2. If the error continues to occur, please con-
tact your retailer.