Connections; Connecting The Mains Voltage; Connecting An External Audio Source; Level Adjustment Studio Music Signal - KBL megaSun 6900 alpha deluxe Manual

Table of Contents

Advertisement

Connections

Connecting the mains voltage

Live parts
Risk of fatal injury due to electric shock
when touching live parts.
• Disconnect from mains and secure
against reconnection!
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection work
must only be performed by qualified expert staff.
The connection to the 400 V mains must be protected
by fuses. Their specifications are listed in the chapter
"Technical data".
A residual current-operated circuit breaker (RCD)
with short time delay is absolutely required. KBL AG
recommends the following type: KBL 3200 0770 00
(type (Typ ABB F 204 A - 40//0,03 AP-R).
Should the operation of the tanning unit cause any
interference in the power supply network, e.g. with
ripple-control systems (TRA), consult your power
supply company to have corresponding blocking
elements (audio frequency suppressors) installed.
8
M a n u a l e o p e r a t i v o | megaSun 6700 - 6800 - 6900
DANGER
Connecting an external audio
source
When connecting an external audio source (studio
music), pay attention to the correct polarity.
Level adjustment studio music
signal
The voice / audio system components are built in
the middle of the bench part (vacuum housing) of
the sunbed. The potentiometer which serves of
the external audio signal is located on the left side
of the housing. To avoid overdrive, select the level
adjustment accordingly. The level setting depends
on the strength of the external signal and should be
carried out by a service engineer. Adjustment of the
sound level can only be conducted in the service
menu.

Advertisement

Table of Contents
loading

Table of Contents