Ventilation and air-conditioning
↵
In order to preserve the performance of the air-con-
ditioning unit, clean the heat exchangers after
500 - 600 hours of operation.
Air-conditioning unit
㊸
㊶
Heat exchanger
㊷
Condensate pump
㊸
Condensate tray
Page
Open the bench part.
42
㊶
Clean the heat exchanger.
Vacuum it carefully, paying attention not to
damage the fins.
㊶
㊷
SERVICING THE VENTILATION SYSTEM
⇒
Check all hose connections.
Remove any kinks in the air hoses. Replace
⇒
defective hoses immediately.
The exhaust air hose must not exceed a
maximum length of 6 m if there is no auxiliary
fan installed.
CHECKING THE CONDENSATE PUMP
The condensate pump ㊷ pumps away the
condensation water at timer-controlled intervals.
Check the function of this pump with each tube
replacement.
Fill some water into the condensate tray ㊸.
⇒
Use a hose and a funnel to do so.
Make sure that the water does not spill over.
Start a tanning session and then wait for 20
⇒
minutes.
The filling level of the tray must then be below
⇒
the pump level.