5.2
Wall mounting the charging
cabinet
LBB 4560/50 is suitable for either table-top or wall-
mounted use.
It can be wall-mounted using 5 mm (0.19 inch) screws,
with a head diameter of 9 mm (0.35 inch). The screws
and plugs delivered with the LBB 4560/50 are
designed to mount the unit on a solid brick or concrete
wall. Two holes, 8 mm in diameter and 55 mm in
depth, must be drilled 500 mm apart (see figure 5.2).
Warning: To comply with UL and CSI reg-
ulations, the charging cabinets must be
mounted in such a way that they can be
easily removed by hand in case of emer-
gency.
Figure 5.2
Charging cabinet mounting dimensions
Bosch Security Systems | 2003-02 | 3122 475 22011en

5.3 Charging procedure

Ensure that the charging unit is connected to the mains
and that it is switched on. Place the receivers firmly in
the charging compartments. The charging indicator
LEDs on all receivers should illuminate. These LEDs
indicate the charging status of each receiver:
LED colour
Charging status
Green
Charging completed.
Red
Charging in progress.
Red blinking
Error status. See chapter 6,
Trouble-shooting.
Off
Charger switched off or receiver not
properly inserted.
Notes:
It is preferred to switch on the charg-
ing unit before inserting the receivers.
Receivers can be inserted or removed
without damage while the charging
unit is switched on.
Charge the battery pack to full capaci-
ty before using them for the first time.
The charger always applies fast
charge during the first 10 minutes
after inserting a receiver. Inserting the
receiver multiple times with a fully
charged battery pack should therefore
be avoided, as this will damage the
battery pack.
Continuously charging the receiver
will not damage the receiver or bat-
tery pack. Receivers can therefore
safely be left in their charging posi-
tions when they are not used.
When the rechargeable battery pack
is used, it is advisable to check regu-
larly after three years that the batter-
ies are not leaking. If there is any sign
of leakage or corrosion, replace the
battery pack. Ensure that only the bat-
tery pack LBB 4550/00 is used. The
battery pack has to be replaced at
least every five years.