1/ LOCATION
Since the temperature measurement sensor is inside the box, you
must install the thermostat flush-mounting box:
- On an accessible wall at a height of 1.50 m
- away from heat sources (fireplaces, sunlight) and draughts
(windows, doors)
IMPORTANT: Do not install the thermostat on a wall in contact
with the outdoors or with an unheated room (e.g. garage, etc.)
The sleeve output in the flush-mounting box must be blanked off
(with mastic) in order to avoid unwanted air movements that could
bias the sensor reading.
environ
1,50 m
Mini 20 cm
4
2/ MOUNTING
Switch off the mains power before handling
the device.
❶ Use a screwdriver to lift off the cover.
❷ Separate the thermostat from its base
unit by loosening the clamp screw ❶
(captive screw).
❸ Only attach the base to a flush-mounted
box (distance between centres 60 mm).
Note: the base unit must be attached using
3 screws.
EN
1
2
5