8/ Return To Initial Settings; Partial Initialisation; All Settings Initialised - DELTA DORE TYBOX BUS OT Installation Instructions Manual

Hide thumbs Also See for TYBOX BUS OT:
Table of Contents

Advertisement

8/ RETURN TO INITIAL SETTINGS
8.1 PARTIAL INITIALISATION
Turn the selector knob to Shutdown ( ).
❶ Press the left button and the
simultaneously for 10 seconds
until 'Init' displays.
❷ To validate, press the OK button for 5
seconds. The 'Init' indication flashes for
5 seconds, then return to the shutdown
screen.
To exit without confirming, press C or
turn the selector knob.
List of parameters and initialised data:
- Temperature settings (Comfort 19°C,
Economy 15.5°C, Frost protection 7°C,
Absence 7°C),
- User configuration (CF01 to CF08).
- Weekly programming
(Comfort 6:00AM to 11:00PM).
- Operating mode (back to Shutdown mode)
- Back-up data (boiler maintenance counter,
number of days of absence).
20
AUTO
i
PROG
button
>10s
1
2
AUTO
PROG
8.2 ALL SETTINGS INITIALISED
This mode resets all the configuration
settings, settings, and programming.
Only the date and time are kept.
Turn the selector knob to Shutdown ( ).
❶ Press the left button and the
simultaneously for 20 seconds. After 10
seconds, the screen displays 'Init', press and
hold until 'ALL' is displayed.
❷ - To validate, press the OK button for 5
seconds. The 'Init' and 'ALL' indications flash
for 5 seconds, then return to the shutdown
screen. The values and settings are initialised.
>5s
- To exit without confirming, press C
or turn the selector knob.
List of parameters and initialised data:
- Settings and data of the partial initialisation.
- Installer settings (PI01 to PI13).
AUTO
PROG
i
button
>20s
1
2
AUTO
PROG
EN
>3s
21

Advertisement