1/ Location; 2/ Connection; 2.1 Circulator Control - DELTA DORE TYBOX 5000 Installation Instructions Manual

Hard-wired room thermostat for boiler

Advertisement

1/ LOCATION

Since the temperature measurement sensor is
inside the box, you must install the thermostat 
fl   ush-mounting box:
- on an accessible wall at a height of 1.50 m
- away from heat sources (fi   replaces, sunlight) and 
draughts (windows, doors)
IMPORTANT: Do not install the thermostat on
a wall in contact with the outdoors or with an
unheated room (e.g. garage, etc.) The sleeve output 
in the fl   ush-mounting box must be blanked off (with 
mastic) in order to avoid unwanted air movements
that could bias the sensor reading.
4

2/ CONNECTION

The diagrams provided are simplifi   ed for greater 
clarity. Protections and other accessories required
by standards are not illustrated. - Standard NF
C15-100 and good practice must be complied
with. Connected or nearby units must not
generate excessive interference
(directive 89/336/EEC).

2.1 Circulator control

L
N
2A max. / 230V~
Circulator
5
EN
2A m
2A m