INSTALLATION
1. Installing the transmitter
1.1 Location
The thermostat can be wall-mounted in a room
where the temperature is to be regulated from,
at a recommended height of 1.5m and away from
any heat sources (fireplace, direct sunlight, etc.)
or draughts (window, door, etc.).
To avoid unwanted air movements that would
distort the sensor measurement, the wire entry
into the flush-mounted box must be plugged
(mastic, glass wool, etc.).
IMPORTANT: Do not install the thermostat on a
wall in contact with the outside or with an
unheated room (e.g. garage, etc.).
1.2 Mounting/Connection
❶ Switch off the power to your setup.
❷ Separate the box from its base.
❸ Connect and secure the base. Your Tybox
must be connected with flexible or rigid cables
with a maximum cross-section of 1.5 mm².
❹ Insert the batteries
WARNING: make sure you insert the batteries
facing the right way and that they are the right
type (no lithium batteries).
❺ Toggle the switch to choose the programme
type: weekly (A) or daily (B).
❻❼ Close and lock the box.
❽ Turn on the power to your setup.
OFF
Ø max. 1,5 mm²
Circulator control
L
N
Thermostat input control
R
C
T
1 2 3
~1,50 m
Mini 20 cm
R
C
T
1 2 3
Th
PROG x 7
PROG x 1
ON
3