Alarm Connections; Table 3-3. Alarm Pinouts; Figure 3-8. Total Access 1224 Alarm Connection - ADTRAN NetVanta 1224 Installation And Maintenance Practice

Quad t1 ima 24-port dslam
Hide thumbs Also See for NetVanta 1224:
Table of Contents

Advertisement

Total Access 1224 Quad T1 IMA 24-Port DSLAM Installation and Maintenance Practice

Alarm Connections

The Total Access 1224 provides an Type SP15 connector (see
alarm inputs and three alarm outputs (Major, Minor, and Critical). If load shedding is active
then the Critical alarm output will be active. Alarm inputs are activated by shorting A and B
contacts (closing an externally connected relay). The outputs provide both normally open and
normally closed pins (through internal relay contacts) for proper operation with a variety of
alarm panels. Each alarm event generates an autonomous TL1 message that is transmitted
via the in-band management channel to a monitoring device.
A cable with a Type SP15 male connector on one end and a stub at the other end is available
(P/N 1196DB901L1) for wire-wrap connections to an alarm panel.
POTS PORTS 1-24

Figure 3-8. Total Access 1224 Alarm Connection

The alarm pinouts are shown in
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
3-12
ADSL+POTS PORTS 1-24
Table
3-3.

Table 3-3. Alarm Pinouts

Color
Red
Red/Black
Red/White
Orange
Orange/Black
White
White/Black
Black
Black/White
Blue/Black
Blue/White
Blue
Green/Black
Green/White
Green
Figure
3-8) with three auxiliary
Alarm Connection
1179621L1
EXPANSION
OUT
Contact Description
Alarm 3 Input - A
Alarm 1 Input - B
Critical Alarm COM
Minor Alarm COM
Major Alarm COM
Alarm 3 Input - B
Alarm 2 Input - A
Critical Alarm NC
Minor Alarm NC
Major Alarm NC
Alarm 2 Input - B
Alarm 1 Input - A
Critical Alarm NO
Minor Alarm NO
Major Alarm NO
FAN MODULE
1179675L1
3.0
61179621L1-5C