06. Features

Auto-Restart After Power Failure
Should a power failure occur whilst the air conditioner is running,
1
the wall control will restart the air conditioner in the same mode
when the power is restored, if this option is selected.
Dual/Triple Wall Control Operation (Optional)
Up to three wall controls can be installed on one system. This is
particularly useful on larger buildings, where you can have up
2
to three wall controllers in different locations. All connected
controllers will mimic any adjustment made in one controller
(restrictions apply).
Room Temperature Display with One Touch
3
Press the
change to show the room temperature for 10 seconds.
Auto Defrost Function (Heating Mode)
At certain outdoor conditions (low temperature) there may be a
build up of frost on the outdoor heat exchanger. This gradual build
up of frost reduces the performance of the air conditioner. The
4
system detects this frost build up and will automatically activate the
defrost mode.
The defrost mode is displayed on the wall control by flashing the
DEFROST indicator every 10 seconds.
Hot Start Function (Heating Mode)
When the air conditioner starts in heating mode, the indoor fan is
delayed for a short period of time, this allows the heat exchanger
5
to warm up before the air flow starts, thus minimising cold drafts.
The hot start feature also activates itself when the system finishes
defrosting.
Filter Clean Light
The system monitors the accumulated run time of the air
6
conditioner and after a preset number of hours have expired,
the FILTER indicator will flash, indicating it's time to check if filter
requires cleaning.
Self Diagnosis
In the unlikely event that a fault develops with the air conditioner
7
the system will detect a fault and displays the relevant fault code on
the wall control.