4-24. List of parameters

Classifica-
tion of pa-
No.
Parameter name
rameters
Automatic
P1
Clamp is opened after
the completion of auto-
machining
matic machining
P2
Number of stitches to be
sewn at the beginning
and end of sewing with
the intermediate presser
lowered
P3
Thread trimming after
the completion of auto-
matic machining
P4
Position to which the
needle is returned after
the completion of auto-
matic machining
P5
Whether or not the
thread tension is re-
quired to be lowered
P173
Clamp foot is retained
when setting a refer-
ence
P259
Automatic operation of
the clamp
P240
Clamp operation in prior
to the manual feed
P6
Number of stitches to be
sewn with overlapped at
the beginning of sewing
P7
Number of stitches to be
sewn at the beginning
of sewing without the
thread tension release
mechanism
P147
Height of the interme-
diate presser when it is
lowered at the begin-
ning of sewing
P148
Height of the interme-
diate presser when it is
lowered at the end of
sewing
Standard
Range
value
Yes/No
Yes
0 to 8
2
Yes/No
Yes
Origin / secondary
Origin
origin
Yes/No
No
Yes/No
No
Yes/No
No
Yes/No
No
OFF / 1 / 2
OFF
0 to 255
0
0 to 4
0.5
0 to 4
0.5
– 40 –
Meaning of parameter and comment
Cassette clamp is lifted every time the
continuous sewing cycle is completed
Number of stitches during which the in-
termediate presser presses the material
at the beginning and end of sewing
Thread trimming is carried out every
time the continuous sewing cycle is
completed.
"Origin" is the origin of absolute coordi-
nates.
"Secondary origin" is the secondary
origin (offset point) added to the pattern.
Whether or not the tension on the
thread is loosened during jump
The clamp foot is retained while a refer-
ence is being set.
On the "Main screen", keep the clamp
foot held at its current position while
moving the shaft. (Lifted or lowered)
The "Main screen" is displayed after the
operation panel is started up.
Whether the cassette clamp is turned
ON at the beginning of sewing
Whether the cassette clamp is turned
ON before the manual feed is carried
out
In the case of set value "1" or "2", sew-
ing is carried out once or twice in rep-
etition at the first needle entry position
before proceeding to the next needle
entry position at the time of starting the
sewing machine.
Setting of the number of reverse feed
stitches at the beginning of sewing
In the case of "OFF", the sewing ma-
chine does not repeat sewing
The thread tension release mechanism
is turned OFF while the sewing machine
sews the set number of stitches at the
beginning of sewing
Intermediate presser height at the be-
ginning of sewing
Intermediate presser height at the end
of sewing