E063 Main axis software over
current
E064 Main axis encoder failure
E065 Main axis locked rotor
E066 Main axis detection for
locked rotor
E067 Y servo hardware protec-
tion
E068 Y servo HOC
E069 Y servo AD module initial
correction fault
E070 Y servo parameter storage
exception
E071 Y servo system parameter
is abnormal
E072 Y Servo Ad sampling mod-
ule failure
E073 Y servo encoder discon-
nected
E074 Y servo encoder AB inter-
ference
E075 Y servo encoder Z interfer-
ence
E076 Y servo bus undervoltage
E077 Y servo software over cur-
rent
E078 Y servo motor overload
E079 Y servo motor overload
E080 Y servo driver overload
E081 Y servo motor overheated
E082 Y servo drive overheated
E083 Y servo fan is abnormal
Fault Cause
1. The parameters are incorrect.
2. The motor is stuck
3. The motor is broken or the motor
wire is broken and short circuited
4. Power board is broken
1. Poor encoder wiring
2. The encoder is damaged
1. The load is too heavy
2. The spindle is mechanically stuck
The spindle load is too large
1. The motor is broken or the motor
wire is broken and short circuited
2. The motor is stuck
3. Y servo board is broken
4. The parameters are incorrect
Abnormal memory chip
Parameter configuration error
1. Y servo encoder has poor contact
or disconnection
2. Y servo motor is broken
3. Y servo board is broken
1. The Y servo board program is the
old version
2. Poor contact or broken wire of the
servo encoder
Motor overload
– 49 –
Solution
1. Reset or redirect parameters
2. Check the machinery
3. Check and replace the motor
4. Replace the power board
1. Check the motor encoder wiring
2. Replace the spindle motor
1. Lighten the load
2. Check the machine
Check the spindle mechanical structure for
problems
1. Check and replace the motor
2. Check the machinery
3. Replace Y servo board
4. Reset or redirect parameters
Spare alarm
E028
Refer to
Error Handling Method
Replace the chip
Check parameter configuration
E028
Refer to
Error Handling Method
1. Check the Y servo encoder line
2. Replace Y servo motor
3. Replace Y servo board
1. Look at the screen "Internal Drive" - "Y
"Version Number", 1 means the old ver-
sion needs to be returned to the factory
to update the program
2. Check the encoder cable
Refer to
E074
Error Handling Method
E410
Refer to
Error Handling Method
Spare alarm
Refer to
E023
Error Handling Method
E026
Refer to
Error Handling Method
Refer to
E026
Error Handling Method
Lighten the load
E029
Refer to
Error Handling Method
Spare alarm