Error
Error description
Code
E402 (0x) Driver board HOC
E403 (0x) Driver module AD mod-
ule initial calibration failure
E404 (0x) Drive board parameter
storage error
E405 (0x) Driver board system
parameters are abnormal
E406 (0x) Driver board AD sam-
pling module is faulty
E407 (0x) The driver board en-
coder is disconnected
E408 (0x) Driver board encoder
AB interference
E409 (0x) Driver board encoder Z
interference
E410 (0x) Driver board bus un-
dervoltage
E411 (0x) Driver board bus over-
voltage
E412 (0x) Driver board software
overcurrent
E413 (0x) Drive board motor
overload
E414 (0x) Drive board drive over-
load
E415 (0x) Driver board motor
overheating
E416 (0x) Driver board driver
overheating
E417 (0x) Drive board fan error
E418 (0x) Drive board overspeed
Fault Cause
1. Abnormal memory
2. Not enough memory
There is a problem with the drive
1. The encoder of the driver board is
poorly connected or disconnected
2. The motor is damaged
3. The motherboard is damaged
1. The driver program is an old ver-
sion
2. Poor contact or broken wire of the
servo encoder
1. Voltage drop
2. The bus load is too heavy
3. Transformer failure
1. Excessive friction increases the
operating load
2. Insufficient power or improper
adjustment of internal parameters
1. Wiring error
2. The acceleration is too high
3. The grid voltage is too low
4. The driver power is low
5. The driver is shorted to ground
– 58 –
Solution
Spare alarm
Spare alarm
1. Maintenance memory
2. Expand memory or clear data
Update drive
Refer to
E028
Error Handling Method
1. Check the encoder cable of the driver
board
2. Replace the motor
3. Replace the motherboard
1. Look at the screen "Internal Drive" - "Y
Servo" - "Version Number", 1 means the
old version needs to be returned to the
factory to update the program
2. Check the encoder cable
Refer to
E408
Error Handling Method
1. Increase the voltage
2. Reduced load operation
3. Repair or replace the transformer
Spare alarm
Refer to
E023
Error Handling Method
E026
Refer to
Error Handling Method
1. Lubrication
2. Adjust the gain or adjust the parameters
Spare alarm
Refer to E029 Error Handling Method
Spare alarm
1. Check the line
2. Reduce acceleration
3. Check the input power
4. Choose the driver with large power level
5. Check whether the drive is short circuit-
ed to ground

Hide quick links: