6 Set up with the display and adjustment module
Sensor status
Peak values, distance
Peak values, measure-
ment reliability
36
To maintain the function of the device, the lighting is temporarily
switched off if the power supply is insufficient.
In delivery status, the lighting is switched on.
6.4.3 Diagnostics
In this menu item, the device status is displayed.
When the instrument displays a failure message, you can here get
detailed information on the failure reason.
The respective min. and max. measured value is saved in the sen-
sor. The two values are displayed in the menu item "Peak values,
distance".
In another window you can reset the peak value.
The respective min. and max. measured values are saved in the
sensor. The two values are displayed in the menu item "Peak values,
measurement reliability".
The measurement can be influenced by the process conditions. In
this menu item, the measurement reliability of the level measure-
ment is displayed in mV. The higher the value, the more reliable the
measurement.
In another window you can reset the peak value.
VEGAFLEX 82 • Profibus PA