4.4. Data Processing Unit

(2)
(1)
DC cable
AC cable
Power switch
button
(1)
(3)

4.4.1. Startup DPU

1) Turn "ON" the power of DPU.
2) Enter the following below if DPU is asking for login:
User name: radar
Password: radar
3) RainMap (Software for the radar operation) will startup automatically after DPU turned on.
4) Remain a safe distance from radar. Radar transmit radio wave can damage human body
especially eyes within the danger zone.
5) Plug in the power cable of ATU/JCU to the local outlet.
6) Turn on the breaker in the Junction Unit to turn on the power of ATU.

4.4.2. Add external data storage

The most common way users save observed data
in to the external HDD for temporary and transfer
it via network.
Adding an external HDD is easy, it just plug-in a
USB3.0 cable into USB3.0 connector of DPU and
external HDD. Then, check the directory path of
external HDD from [Computer] -> [Hard Disk Drives]
screen of DPU.

4.4.3. Renew A-threshold

1) Click [Connect] in the pull-down menu of [Radar
operation] to start RainMap operation.
2) Press [Alt]+[Ctrl]+click [Renew A-threshold] for
adjusting the radar A-threshold. It will take
approx.10 minutes to complete. (Refer to the
Operators manual for detail)
(4)
(6)
(3)
(5)
(4)
(6)
(5)
Setup Data Processing Unit
(1) Connect DC power cord of DPU-PS to DPU.
(2) Connect AC power cord to DPU-PS and AC
power cable to electrical outlet.
(3) Connect DVI cable from LCD monitor to
DPU. Also connect the power cord from
LCD monitor to a local power outlet.
(4) Connect LAN cable from LAN port 1 in JCU
to DPU LAN port 1.
(5) Connect USB/LAN adapter that LAN will be
from MONI-CON (inside the ATU). Other
USB ports are using for keyboard, mouse,
and external HDD.
(6) Connect LAN cable from router to LAN port
2 for using Internet. The router and the LAN
cable for Internet is local supply.
Notice:
1> Bundled cable is dedicated for Japan/US use
and can be used up to 125V. Therefore the
local user will be necessary to prepare a
replacement power cords (e.g. 200-240V) for
local use. (Refer to Appendix D)
2> Do not use the same IP address on ATU.
3> Do not put heavy object on the DPU. It may
deform the DPU chassis.
35