Air Restrictors Installation - Valor Portrait 530ILN Installation & Operating Instructions Manual

Portrait direct vent gas fireplace heater
Hide thumbs Also See for Portrait 530ILN:
Table of Contents

Advertisement

Attaching Air Restrictors—Appliances with Vertical Vent Rise Only
No restrictors are required for appliances which only have a horizontal vent run.
If installing an appliance which has a rear vent outlet connection and no vertical
vent pipe rise, ignore this stage.
Two restrictor sets, like the one shown right, are supplied with each 530 engine unit.
The restrictors cover part of the inlet air openings in the fi rebox rear wall behind the
rear log support.
Each set is assembled with an adjustable piece which can be moved to different
positions depending of the vent confi guration. See the table below to fi nd out which
position is optimal for each type of installation.
• To fi t the restrictors, loosen the two center screws of the left and right inlet ports.
Place the restrictor assembly under the screw heads and tighten the center screws.
• To set the adjustable restrictor piece, loosen the two screws, position the adjustable
piece according to the diagram below and tighten the screws.
Vertical vent
Vent terminal
pipe run
Horizontal
Less than 2 ft
through wall
(61 cm)
(with vertical
rise)
From 2 ft
(61 cm) but
less than 4 ft
(122 cm)
From 4 ft
(122 cm) but
less than 6 ft
(183 cm)
6 ft (183 cm)
or more
Vertical
Less than
through roof
13 ft (396 cm)
13 ft (396 cm)
or more

Air Restrictors Installation

Use restrictor setting
Logs/Rocks
Coals
Air Restrictor
Install restrictors in the inlet air openings
in the fi rebox rear wall behind the rear log
support.
Adjustable
piece
19
19